Modelled dry years (1997 - 2005) average annual diffuse recharge (mm/yr)
dataset:
ENSYM_RECHARGE100_DRY
Modelled dry years (1997-2005) average annual diffuse recharge (mm/yr) as calculated using the Ensym model. Includes rainfall recharge and irrigation recharge however excludes river/stream/channel/reservoir leakage.
Ensym estimates daily spatial recharge by solving for physical processes using analytical solutions and empirical equations. Water entering the soil profile is initially determined by subtracting the calculated surface runoff from the total daily precipitation and irrigation. Once in the soil profile, water can be removed by evapotranspiration, lateral flow and downward movement if soil capacity is exceeded. Water fills up lower soil layers until it exits the soil profile and becomes drainage. Drainage is then partioned into sub surface lateral flow and recharge.
For further information:
https://ensym.dse.vic.gov.au/home/aboutensym
Beverly, C., 2007. Technical Manual - Models of the Catchment Analysis Tool. Victoria. Department of
Sustainability and Environment.
|
Citation proposal Citation proposal
(2013) Modelled dry years (1997 - 2005) average annual diffuse recharge (mm/yr) Department of Energy, Environment and Climate Action https://metashare.maps.vic.gov.au/geonetwork/srv/eng/catalog.search#/metadata/8c062c57-3284-5ffb-a1df-8aa715a5e1cd |
- Description
- Temporal
- Spatial
- Maintenance
- Format
- Contacts
- Keywords
- Resource Constraints
- Lineage
- Metadata Constraints
- Quality
Description
- Title
- Modelled dry years (1997 - 2005) average annual diffuse recharge (mm/yr)
- Alternate title
- ENSYM_RECHARGE100_DRY
- Resource Type
- Dataset
- Purpose
- Modelled recharge data can be used for: - water balance estimates - groundwater modelling inputs - landuse change impact modelling - effluent disposal
- Supplemental Information
- Related Documents: None
- Status
- Completed
Temporal
- Time period
- 2011-10-012011-11-28
Spatial
- Spatial representation type
- Grid
- Horizontal Accuracy
- 100m
- Code
- 4283
- Description
- General - Victoria
N
S
E
W
Maintenance
- Maintenance and update frequency
- As needed
Format
- Title
- DIGITAL - ArcView ascii grid 3
Contacts
Point of contact
Department of Energy, Environment and Climate Action
-
Charles Showers
1 McKoy street
Wodonga
Vic
3690
Australia
Cited responsible party
No information provided.
Cited responsible party
No information provided.
Cited responsible party
No information provided.
Keywords
- Topic category
-
- Inland waters
- Geoscientific information
- Climatology, meteorology, atmosphere
Resource Constraints
- Use limitation
- Available under license. All use must be approved by the DSE ecoMarkets data custodian.
- Classification
- Unclassified
Lineage
- Statement
- Dataset Source: Recharge estimates are sourced from the DSE Ensym model. Dataset Originality: Primary
Metadata Constraints
- Classification
- Unclassified
Quality
Attribute Quality
- Comments
- Estimates of recharge vary in accuracy based on input datasets. Variability in soil mapping adds the highest uncertainty in recharge estimates.
Positional Accuracy
- Comments
- Precision: 10 - 100m Determination: Based on the scale of input datasets
Conceptual Consistency
Missing Data
- Comments
- State of Victoria
Excess Data
Overviews
Provided by
Views Views
8c062c57-3284-5ffb-a1df-8aa715a5e1cd
Access to the portal Access to the portal
Read here the full details and access to the data. Read here the full details and access to the data.
Associated resources
Not available